Software > Technical Software > Technical Software (Miscellaneous) > WDurch
Heat transfer calculation not for heating and building construction

WDurch

Heat transfer calculation not for heating and building construction

Version:  6.1

 
 
 
 
 
 
 
 
Demo version

Software for calculating heat transfer for industrial furnaces and refrigeration technology

Heat transfer is the transfer of heat from a warmer substance in a gaseous or liquid state through a solid wall to a colder substance in a liquid or gaseous state. Heat transfer is made up of three processes. The heat transfer from the warmer substance to the wall surface, the heat conduction through the wall and the heat transfer from the wall surface to the colder substance.

The solution supports you perfectly and at the same time simply in calculating the heat loss of a stove wall or technical thermal insulation and in determining the temperature curve through the wall of a stove, which leads to the optimum design of the various wall layers.

    Heat transfer according to:

    • ASTM C680, EN ISO 12241, VDI 2055
    • on vertical wall, ceiling, floor, cylinder, dome, fitting
    • Diagram with max. 20 layers in color
    • File temperature-dependent thermal conductivity values (30 in the standard version)

    Advantages

    • Extremely user-friendly and self-explanatory design
    • Numerous information and safeguards against operating errors
    • Selection of materials from the material list with headings
    • Variants can be easily changed and saved
    • Calculations can be saved in projects.

    Features (excerpt)

    • Results displayed as diagrams
    • Output of the calculation as a table
    • Export of calculations to writing systems
    • Surface: flat wall, dome, fitting, cylinder (also internally cooled)
    • Temperature-dependent thermal conductivity coefficients (also in H2-containing atmosphere)
    • A factor and a surcharge for thermal bridges can be added to the thermal conductivity coefficients
    • Heat transfer in a vacuum (radiation only)
    • Internal heat transfer (hot side) calculated from: internal dimensions of the furnace, internal emissivity, convection, gas radiation from H2O, CO2, CH4

    Not suitable for construction (heating and building construction).

    • Additionally for net 420 EUR: File for over 1600 substances
    • Alternative: Mini version: 4 layers without mat file net 570 EU

    No training is required. The program does not require any special hardware requirements or third-party programs.

    Target groups:

    • Thermal insulation
    • Industrial furnace construction
    • Refractory
    • Refrigeration technology
    • Acid construction

    References:

    • AHKO GmbH Refractory (internal Insulation) D-44149 Dortmund,
    • UNIFRAX GmbHKleinreinsdorf D-07989 Teichwolframsdorf,
    • BURWITZ Feuerungsbau GmbH D-31224 Peine,
    • BECKMANN Feuerungsbau D-25368 Kiebitsreihe,
    • CORUS R,D & T(steel)NL-1970 CA Ijmuiden
    • DO THERM Insulation materials D-44293 Dortmund,
    • ENETEX GmbH D-36396 Steinau an der Straße,
    • PURMETALL GmbH & Co.KG D-46049 Oberhausen,
    • WESTRO GmbH Feuerungsbau D-46049 Oberhausen,
    • Insulcon B.V. NL-4651 SP Steenbergen,
    • SCHNEIDER Dämmtechnik AG CH.8401 Winterthur

    140 References see www,f-soft.com

    Contact information:
    Mr. Dipl.-Ing. Joachim Fritsche
    02630 8286
    Links & Downloads:
    Information
    direct to webpage
    Request online demonstration
    request meeting
    Success story
    direct to webpage
    Software exposé
    request URL

    Functions (excerpt) of WDurch:

    Calculations
    Data selection
    Diagrams
    Export functions
    Heat calculation
    Multilingualism
    Spreadsheet

    Price

    from 1,500.00
    EUR
    plus 19% VAT
    Standard version

    Get to know the software better! Request a video appointment for a personal presentation!

    Technical specifications:

    Web-based:
    no
    SaaS, Cloud:
    no
    On-premises (local installation):
    yes
    AI Supported:
    no
    Multi-user (network-compatible):
    yes
    Maintenance:
    not required
    First installation (year):
    1988
    Number of installations:
    über 100
    Manufacturer based in:
    Germany
    Training:
    not required
    Hotline:
    included in price
    Installation support:
    not required
    Documentation:
    Demo version, Technical documentation
    Dialogue language(s):
    Serbian, Swedish, Polish, Croatian, Korean, Japanese, Italian, French, English, Danish, German, Chinese, Bulgarian, Slovak, Spanish, Czech
    System requirements:
    Compatible operating systems (runs with):
    Win 11
    Win 10
    Win Server
    Mainframe based
    Unix based
    Linux based
    Mac OS
    Mobile OSs (supports):
    iOS
    Android
    Old Compatible Operating Systems:
    Win 8
    Win 7
    Win Vista
    Win XP
    Win 9x/ME
    Min. memory requirements:
    1 MB RAM, 21 MB Hard disc
    Data storage medium:
    DVD
    CD-ROM
    Download
    Flash memory
    Other requirements for soft- and hardware:
    from Win 98/NT